- 品牌:英国稳科Wayneker
- 型号:3265B
- 频率范围:20 Hz to 500 kHz
- 加工定制:是
英国稳科wayneker dc bias units 直流电流偏置电源 直流偏压电流源
产品简介:3265b 可提供至25a, 最多可连结5台 . **输出电流可达125a,并可由3260b或3255 series控制电流大小, 并启动/关闭输出来分析电感器在工作状态中铁芯的特性, 检测电感品质及产品特性分析,是为电感器检测的*量测仪器组合
产品特色
•模拟类比线圈之工作状态并测试其特性
•25 ma到 25 a直流偏压输出,0.025 a(微调)
•**电压达到 11 v dc
•适用量测参数 l, r, d, q, z
•量测频率范围20 hz to 1 mhz (3255bl, 3255b, 3255bq)
•量测频率范围20 hz to 3 mhz (3260b)
•基本精确度 1%
•4端点或2端点 量测方式
•最多可并连5台 . **输出电流可达125a
•安全开关保护操作员避免操作不当引起的触电或损坏
•不占空间, 可置于分析仪下方或安装于19 inch 仪器架上
产品规格
3265b 可提供至25a, 最多可连结5台 . **输出电流可达125a,并可由3260b或3255 series控制电流大小, 并启动/关闭输出来分析电感器在工作状态中铁芯的特性, 检测电感品质及产品特性分析,是为电感器检测的*量测仪器组合
dc bias units
3265b/5a 3265b/10a 3265b/20a
3265b/25a 3265bq/25a
enhances usability of wayne kerr analyzers3255bl inductance analyzer3255b inductance analyzer3255bq inductance analyzer3260b precision magnetics analyzerdc bias unit can deliver between 25 ma and
up to 125 a dc bias current in steps of 25 madc bias fixture model 1009 allows accurate and safe testing of smd inductorsadds additional functionality
component tests up to 125 a dc bias currentto evaluate components at high currents the 3265b/25a dc bias units may be used with either the wayne kerr 3255b inductance analyzer or the 3260b precision magnetics analyzer. bias current may beset from 25ma to 25a in steps of 25ma. these units may not be used with a 3255bl.
additional dc bias units can be added in parallel such that with five units connected in parallel it is possible to set bias currents up to a maximum of 125 a dc. for extended frequency, up to 3mhz, 50a is available when two 3265bqs are used.
5a, 10a and 20a models are available which may be connected in parallel to give up to five times the maximum rated dc bias current.
the instruments have a number of safety and protection features including a safety interlock system to protect the user against back emfs. it is also fully protected against over temperature,excess voltage drop and sense lead failure.
3265b/25a dc bias unit can deliver up to 25 a of dc bias current in steps of 25ma
smd inductor tests up to 50 awith the addition of the 1009 dc bias fixture dc bias currents up to 50 a can be applied to an smd inductor during component test in order to evaluate the devices thoroughly at the operationalbias currents.
the fixture operates with either one or two 3265b wayne kerr dc bias units and a 3260b precision magnetics analyzer. the optional 1009 50a lead set, 5-328-2005, will be required if two 3265b/25asare used.
four rear panel mounted bnc connectors and two captive high current cables ensure simplicity and ease of use with the 3265b.
interchangeable component test carriers ensure that the 1009 dc bias fixture may be used with a wide variety of devices. if a device package is not supported by one of the standard carriers then acustom carrier design service is available.
1009 dc bias fixture enables currents up to 50 a to be applied to an smd inductor
stable component fixturing ensures high accuracy and repeatable measurements. enclosed fixtures, with safety interlocks, minimises risk to operators.
technical specificationscompliance voltagesmaximum compliance voltage (10 v compliance at 1 v ac drive level. for f>12 khz deduct 0.5 v.
must be used in conjunction with either a 3260b or 3255bapplicationspermits measurement analysis of wound components with levels of dc bias current higher than the standard 1avariable measuredin impedance mode: l, z, r, q, d.
not applicable to rdc, or transformer measurementsmeasured frequency range3255bl 20 hz to 200 khz (not compatible with 3265b/25a and 3265bq/25a)
3255b 20 hz to 500 khz
3255bq 20 hz to 1 mhz
3260b 20 hz to 3 mhz (3265bq/25a)basic accuracy± 1%.
varies with measurement speed, frequency and options chosen.measurement terminals2-terminals measurement via m8 studs.
4-terminal measurement via kelvin leads and m8 studs.
measurement terminals internally protected by 1.6a fuses against normal inductor back-emf or accidental disconnection of inductor.
front panel fuses easily replaced.control connectionsi2c bus link controls application of dc current and monitors status of analyzer. status data includes excessive voltage drop and over temperatureoptional facilities3265b bias units may be paralleled, maximum of five units.interlockbias safety interlock socket on rear panel of analyzer provides door lock and closed control linestemperature rangestorage: -40°c to 70°c.
operating: 0°c to 40°c (20 a max)
full accuracy: 15°c to 30°c (25 a max)power supplyuniversal 90 to 255 v ac, 47 to 63 hz
input current 9 a rms max.
power factor >0.9
unit powers up automatically when connected to a powered analyzer. isolating switch provideddimensionsheight 190 mm (7 1/2″)
width 440 mm (17 3/8″)
depth 520 mm (20 1/2″)
weight 15 kg (33 lb)coolingfan cooled. intake front, exhaust rear. fan filter accessible on front panel. over temperature trip providedorder codes and options5a dc bias unit 3265b/5a (1 mhz) 1j3265b/5a
10a dc bias unit 3265b/10a (1 mhz) 1j3265b/10a
20a dc bias unit 3265b/20a (1 mhz) 1j3265b/20a
25a dc bias unit 3265b/25a (1 mhz)
not compatible with 3255bl 1j3265b/25a
25a dc bias unit 3265bq/25a (3 mhz)
not compatible with 3255bl 1j3265bq/25a
both units supplied with user manual, power cable, spare fuses, 4 x bnc to bnc links, daisy chain link, rack mounting ears (unit needs rear support) and bus bars.
accessories
kelvin clips leads (fine jaws) 1eva40100
kelvin clips leads (large jaws) 1eva40180
power transfer bus bars (two each per unit in parallel) 4-324-6009
filter pad (washable) hmdec10
1009 dc bias fixture 1j1009
1009 50a lead set 5-328-2005
长沙力高捷创仪器有限公司
吴玉进
18665876229
中意一路66号亚商大厦A栋2524室