- 工艺:注塑/注射
日海保安排,100k10回线保安排,mdf外线模块保安排,普天保安排
日海保安排,100k10回线保安排,mdf外线模块保安排,普天保安排
1. 环境要求:
1) 工作温度: -5℃~+40℃
2) 贮存温度: -25℃~55℃
3) 工作相对湿度: ≤85%(+30℃)
4) 贮存相对湿度: ≤75%
5) 大气压力: 70kpa~106kpa
2. 模块指标:
1) 导线材料:单股塑料绝缘导线;
2) 芯线直径: 0.4-0.6mm;
3) 最大外径(包括绝缘层在内):≤1.4mm
4) 单根导线沿槽口垂直方向的拉脱力:≥25n;
5) 保安器簧片与接线排端子片间的接触压力:f>50g
6) 卡接寿命:>200次
抗电强度:在标准的试验大气条件下承受1000v的交流电压,历时1min无击穿和飞弧现象.
绝缘电阻:在标准的试验大气条件下>1000欧姆
适用导线:单股塑料绝缘铜导线,电缆侧芯线直径:0.32mm-0.6mm
卡接接触电阻 行标:《3欧姆 实际:《0.5欧姆
簧片间接触电阻 行标:《7欧姆 实际:《1欧姆
拉脱力 单根导线沿槽口垂直方向的拉脱力>25n
seainsurancearrangement, 100 k10/19 dated back to the linearrangement, mdfperimeter module arrangement, putian insurancearrangement
sea insurance arrangement, 100 k10/19 dated back to thelinearrangement, mdf perimeter module arrangement, putianinsurancearrangement
1. environmental requirements:
1) working temperature: - 5 ℃ ~ + 40 ℃
2) storage temperature: 25 ℃ ~ 55 ℃
3) work relative humidity: 85% or less (+ 30 ℃)
4) storage relative humidity: 75% or less
5) atmospheric pressure: 70 kpa to 106 kpa
2. the module index:
1) wire materials: single plastic insulated wire;
2) core diameter: 0.4-0.6 mm;
3) the largest diameter (including insulation) : 1.4 mm or less
4) single traverse along the notch is pulled off in the directionofvertical force: p 25 n;
5) protector reed and connection line of contact pressurebetweenthe terminal piece: f > 50 g
6) clamping life: > 200 times
the electric strength: in the standard test under the conditionofatmospheric bear the ac voltage of 1000 v, for 1 minwithoutbreakdown and flashover phenomenon.
insulation resistance: under the condition of standardtestatmosphere > 1000 ohms
applicable wire: single strands of plastic insulated copperwire,cable side core diameter: 0.32 mm to 0.6 mm
card to connect a line contact resistance standard: the 3 ohmreal:the 0.5 ohms
contact resistance between the reed mark: 7 ohm actual: 1 ohm
single conductor pulled off force along the notch is pulled offinthe direction of vertical force > 25 n
慈溪市华创通信设备厂
潘先生
18682183086
慈溪市横河镇孙家境村直河塍59号