长沙分类信息网-长沙新闻网

山东沼气发电机组一套多少钱

2018-11-30 3:57:40发布17次查看
加工定制品牌济柴
型号C53456产品名称济柴
适用范围发电

主动状况
active status
1.坚持发动电动机的蓄电池组到达发动电压。
1. insist on starting the battery of the motor to reach the starting voltage.
2.坚持散热器冷却水位正常,循环水阀常开。
2. adhere to the radiator cooling water level is normal, circulating water valve often open.
3.曲轴箱油位坚持在量油尺刻线 ±2cm的范围内。
3. the oil level of crankcase is kept within the range of + 2cm.
4.油箱油量在一半以上,燃油供油阀常开。
4. the fuel tank is more than half of the fuel supply valve.
5.发电机控制屏的“工作——中止——主动”开关放在“主动”方位。
5. the "work stop active switch" of the generator control panel is placed in the "active" position.
6.机组配电屏的形式开关在“主动”方位。
6. the switch of the power distribution panel is in the "active" direction.
7.散热器风机开关打在“主动”方位。
7. the radiator fan switch is in the "active" direction.
8、机组收到市电失压的信号后发动,承认市电失压,切开变换柜市电开关,合上变换柜发电开关,发动机房的进风和排风机。
8, the unit receives the signal of the power loss of the city, acknowledges the power loss of the city, open the switch of the transformer and switch to the power switch of the conversion cabinet, and start the air and exhaust fan in the machine room.
手动发动
manual launch
1.室内气温低于20℃时,敞开电加热器,对机器进行预热。
1. when the indoor temperature is below 20 c, open the electric heater to preheat the machine.
2.查看机体及周围有无阻碍工作的杂物,如有应及时清走。
2. check whether there are any obstructed objects in the body and surrounding areas. if necessary, clear away in time.
3.查看曲轴箱油位、燃油箱油位、散热器水位。如油位水位低于规定值,应弥补至正常方位。
3. check crankcase oil level, fuel tank oil level and radiator water level. if the oil level is below the specified value, it should make up for the normal position.
4.查看燃油供油阀和冷却水截止阀是否处于注册方位。
4. check whether the fuel supply valve and the cooling water shut-off valve are in the registration direction.
5.查看起动电动的蓄电池组电压是否正常。
5. check whether the voltage of starting battery is normal.
6.检验配电屏的实验按钮,调查各报警指示灯有否接通发亮。
6. check the test button of the distribution panel to investigate whether the alarm lights have been switched on or not.
7.查看配电屏各开关是否置于分闸方位,各仪表指示是否处于零位。
7. check whether the switches in the distribution panel are placed in the position of the switch, and whether the instrument instructions are in zero position.
8.发动进风和排风机。
8. start the air inlet and exhaust fan.
9.按动发动机的起动按钮,使其发动工作。如第一次起动失利,可按下配电屏上相应的复位按钮,待其警报消除、机组回复正常状况方可进行第2次发动。发动后,机器工作声响正常,冷却水泵工作指示灯亮及路仪表指示正常,发动成功。
9. press the start button of the engine to start the work. if the first start fails, the corresponding reset button on the distribution panel can be pressed. the alarm can be eliminated and the unit returned to normal before it can be launched for the second time. after firing, the machine works normally, the cooling water pump indicator lights up and the instrument instructions are normal, and the operation is successful.
济南济柴环能燃气发电设备有限公司
联系人:李经理
固话:0531-62325028
地址:济南市高新区舜华路2000号舜泰广场8号楼西305
网站:http://www.huannengpower.com/
鲁商云:http://www.lushangyun.com
诺商商道系统,-专业互联网应用服务提供商:www.chinanovo.net
诺商商道系统,-专业互联网应用服务提供商:www.cn-un.net
诺商基于多年的优化经验和品牌基础推出的诺商商道系统,诺商信息您身边的互联网专家!

济南济柴环能燃气发电设备有限公司
李先生
15689730223
山东 济南 天桥区
该用户其它信息

推荐信息

长沙分类信息网-长沙新闻网
关于本站