- 药(械)准字:RSD
- 售后服务:
- 型号:
- 产品类别:
- 外形尺寸(mm):
- 重量(kg):
深圳湾边贸易 0755-86216601 品名: rsd肺部/胸部模体英文名:rsdlung/chest phantoms
厂家:radiologysupport devices(美国rsd公司)
rsd lung/chestphantoms
lung/chest with removable diaphragm and lungpairinsert.
low contrast &highcontrast
the next best thing to human lungsforradiographic studies
extensive vascular detail different degrees ofvascularcontrast interchangeable normal andpathologicallungs developed in conjunction with the universityofcalifornia at irvine's department of radiological sciences,thealderson lung/chest phantom is a specialized phantom, providingahigh degree of realism inchestradiography.
thealderson lung/chest phantom extends from the neck tobelow thediaphragm. it is molded about an rsd “superhuman maleskeleton,corresponding to the external body size of a patient, 5'9(175 cm)tall and weighing 162 lbs. (73.5 kg). rsd materials areequivalentto natural bone and soft-tissues. animal lungs areselected tomatch the size of an adult male. lungs are fixed in theinflatedstate and are molded to conform to the pleural cavities ofthephantom. the pulmonary arteries are injected withablood-equivalent plastic.
thelung/chest phantom with simulated left coronary arteryrevealsseveral areas of coronary artery irregularityandnarrowing.
todemonstrate different pathological conditions, fivestandardpathologies are available:
1.two contiguous 0.5 cm nodules at the tip of the firstleftrib.
2.a0.6 cm nodule superimposed with large vessel in the leftlowerlobe.
3.a1.5 cm nodule, left mediastinal shadow.
4.a0.6 cm nodule blending in with the rightpulmonaryartery.
5.pneumonia in the right lowerlobe.
(custom pathologies are availableuponrequest)
thelung/chest phantom is available either with thediaphragmpermanently sealed to the interior of the phantom, fixingthe lungsin place, or with a removable diaphragm, which permitstheinterchange of lungs, and provides an unlimited numberofconfigurations and disease simulations. all models areavailablewith blood-equivalent pulmonary arteries, or with low orhighcontrast media added.
lung / chest phantoms model numbers。 rsd模体订货型号rs-310 lung/chestphantomwith permanently sealed diaphragmrs-315 lung/chestphantomwith permanently sealed diaphragm and leftcoronaryarteryrs-320 lung/chestphantomwith removable diaphragm lung pair insert withoutcoronaryarteryrs-330 lung/chestphantomwith removable diaphragm lung pair insert withcoronaryarteryrs-340 lung/pairinsertwithout coronary arteryrs-345 lung/pairinsertwith coronary artery
深圳市湾边贸易有限公司
张雪凤
13751009778
玉泉路通海苑南108
