长沙分类信息网-长沙新闻网

德国K2L公司Most150总线光纤转同轴电缆EMC和ESD测试

2018-9-1 17:26:25发布47次查看
加工定制类型车载娱乐
检测误差0.001%工作温度-45-85℃
电压12V尺寸11*12*16mm
品牌K2L型号Most150
认证EMC标准ESD

德国k2l公司most150总线光纤转同轴电缆emc和esd测试
most总线设备过emc测试,most总线设备过esd测试,
本产品most150e-o已经过了相关的认证,如emc,re认证,esd认证等。
本产品需要成对使用,其中一个与被测试的most设备连接,放在emc或者esd测试房内,通过光纤引出连到另外一个most150e-o上(将物理层是双绞线的most设备转成光纤,电气影响降到***低)
scope of delivery
the delivery of the most150 e-o converter kit covers the following:
?? most150 e-o converter (qty: 2)
?? optical cable set 40 m (qty: 1)
?? coaxial cables 1 m (qty: 2)
?? converter cable fakra to sma ~0.1 m (qty: 2)
?? power supply (qty: 1)
?? printed user manual (qty: 1)
most总线设备过emc测试,most总线设备过esd测试,
本产品most150e-o已经过了相关的认证,如emc,re认证,esd认证等。
本产品需要成对使用,其中一个与被测试的most设备连接,放在emc或者esd测试房内,通过光纤引出连到另外一个most150e-o上(将物理层是双绞线的most设备转成光纤,电气影响降到***低)
scope of delivery
the delivery of the most150 e-o converter kit covers the following:
?? most150 e-o converter (qty: 2)
?? optical cable set 40 m (qty: 1)
?? coaxial cables 1 m (qty: 2)
?? converter cable fakra to sma ~0.1 m (qty: 2)
?? power supply (qty: 1)
?? printed user manual (qty: 1)
the following tests have been performed for the most150 e-o converter:
?? radiated emissions (re)
?? bulk current injection (bci)
?? electro-static discharge (esd)
the most150 e-o converter duplex is a set of two devices assisting in isolating a most150 coax dut operating on most150 coax full duplex physical layer during a functional emc/esd network test by converting the electrical most physcial layer into an optical physical layer network and vica versa.
one most150 e-o converter device is connected electrically to the most network devices outside of the emc test chamber (this most150 e-o converter is connected to a power supply and automatically charges the rechargeable batteries that are assembled inside) while the other most150 e-o converter is connected electrically to the most network dut inside the chamber. the network is completed when an optical connection is made between the two most150 e-o converters.
with that setup the full blown emc/esd tests can be performed against the dut while another device that is not fully emc robust can be operated outside the emc test chamber.
the major features of the most150 e-o converter duplex include:
conversion between most electrical cphy full duplex network signals and optical physical layer network signals
minimal influence on most electrical cphy network messages
protection of stimulus equipment from harsh test environment in the emc chamber
optical interface operable at lengths up to 40 m
aluminium enclosure with battery power supply to reduce emissions and imporve immunity
on-board battery charger circuit
simultaneous battery charging and powering of the device
low battery indicator