the panametrics-ndt™ series 35 ultrasonic precision thickness gages provide easy-to-use and cost-effective solutions in applications where the opposite side of the test material is difficult or impossible to reach. these rugged, pocket-sized gages make stable, repeatable thickness measurements on most materials of varied shapes and sizes. accurate thickness measurements are displayed in large numerals on the backlit lcd or can be viewed along with the live waveform in the optional a-scan mode.
35 series features
• velocity and reduction rate measurements are standard on all models
• wide thickness range from 0.0030 to 25.0 (0.08 mm to 635.0 mm) depending on instrument and material
• uses contact, delay line, and immersion transducers
• application auto-recall with default and custom setups
• hand-held; weighs only 8.5 oz. (0.24 kg)
• min/max mode
• hi-low alarm
• english and metric display (inches/mm)
• multi-language user interface
• long battery life
models 35 and 35dl
models 35 and 35dlare used in the majority of applications
the 35 and 35dl can use transducers ranging from 2.25 to 30 mhz, which means that these versatile gages can solve the majority of thickness gaging applications, from very thin to very thick. in general, transducers with higher frequencies and smaller diameters allow measurements of thinner or curved parts and enhance the accuracy of the measurement.
applications
• most materials, from thin to thick
• plastic bottles, tubes, pipes, sheets as thin as 0.08 mm (or 0.003 inch)
• metal containers, steel coils, machined parts as thin as 0.10 mm (or 0.004 inch)
• cylinder bores, turbine blades
• glass bulbs, bottles
• thin fiberglass, rubber, ceramics, and composite materials
• curved areas or containers with small radii
• resolution up to 0.001 mm or 0.0001
models 35hp and 35dl-hp
with a very low ultrasonic frequency bandwidth and a special pulser-receiver, the hp gages are specifically designed to optimize ultrasound penetration when measuring thick, highly sound attenuating or sound scattering materials. typically these materials cannot be measured with most other ultrasonic thickness gages.
applications
• most thick or sound-attenuating materials
• thick cast metal parts
• thick rubber tires, belts
• fiberglass boat hulls, storage tanks
• composite panels
• resolution of 0.01 mm or 0.001
of 0.01 mm or 0.001
the 35hp gages are excellent tools to measure fiberglass or composite parts, from aerospace structures to boat hulls and storage tanks that require thickness control.
why hp gages
for more than three decades, panametrics-ndt thickness gage engineers have developed the hp (high penetration) series specifically for very sound-attenuating or thick materials. not only can these gages use transducers as low as 0.5 mhz but their electronics (pulser-receiver) are highly optimized to process signals at these low frequencies. the result is that the panametrics-ndt gages have earned a reputation for superior performance in measuring thick rubber, fiberglass, composites, and other tough materials.
other 35 series features
with reduction rate you can measure critical thickness metal thinning caused by bending.
reduction rate measurements
differential mode and reduction rate mode are standard features on all models. differential mode shows the thickness variation from a pre-set thickness value. reduction rate calculates and displays the percent of thickness reduction after a material thinning process. a typical application is automotive sheet steel that is bent and formed to make car body panels.
velocity measurement mode with direct velocity readout.
material sound velocity measurements
all 35 models have the capability to make material sound velocity measurements. this standard feature is useful in applications where the speed of the sound within the material can be correlated to other properties. typical applications include cast metals to monitor the degree of nodularity, and composites/fiberglass to monitor variations in density. olympus ndt offers a digital caliper for automatic transfer of measurement thickness.
application auto-recall simplifies gaging
application auto-recall simplifies making thickness measurements. select any of the stored transducers and the 35 gages recall all relevant internal transducer parameters.
stored standard setups
standard setups include most commonly used transducers.
stored custom setups
just in case your special application problem cannot be solved with a standard setup, these gages can create, store, and recall as many as 20 custom setups (10 with the 35 and 35hp).
micrometers won't work in this classic application. instead, the model 35 with a m208 transducer makes a thickness measurement up to a calibrated accuracy of 0.001 mm (or 0.0001 inch) without breaking the glass .
thickness and waveform of a very thin (0.004 inch or 0.10 mm) sheet of steel.
35pcscope
optional 35pcscope interface software permits the instant display of live ultrasonic waveforms and thickness readings directly on your computer screen. this is helpful when setup parameters require closer examination.
now you can see the live waveform and make adjustments
operator can view thickness and waveform with the optional a-scan mode
an optional live waveform mode on all models permits the user to view the ultrasound waveform (or a-scan) directly on the gage's display to make sure the thickness reading is correct. the adjust mode feature facilitates transducer setup adjustments to maximize measurement performance for challenging applications.
• high pixel density lcd renders sharp trace of live waveform
• permits real-time verification of thickness readings
• helps solve many difficult applications
• a range, delay, or zoom allow enlarging and centering to any section of the waveform
• permits adjustments of transducer setup parameters
• stores waveforms in data logger and transfers to pc
why ultrasonics?
ultrasonic measurements are accurate, reliable, and repeatable. instant digital readings can be achieved by transmitting sound into just one side of a material, making it unnecessary to cut or destroy parts where the opposite side is difficult to reach and where micrometers or other inspection tools cannot do the job.
35, 35dl, 35hp and 35dl-hp specifications*
measurements
mode 1:
time interval between excitation pulse and first back wall echo, using contact transducers.
mode 2:
time interval between the first interface echo after the excitation pulse and the first backwall echo, using delay line or immersion transducers.
mode 3:
time interval between successive back wall echoes following the first interface echo after the excitation pulse, using delay line and immersion transducers.
measurement types: thickness, velocity, or time of flight
thicknessmeasurement range*:
0.003 - 25 inches (0.08 - 635 mm)
*thickness range depends on model, material, transducer, surface condition, and setup selected.
materialvelocity range:
0.02000 - 0.7362 inch/µs
0.5080 - 18.699 mm/µs)
resolution (keypad selectable):
low:
0.01
(0.1 mm)
standard:
0.001
(0.01 mm)
high:
0.0001
(0.001 mm)
(35 & 35dl)
time of flight measurement range:
0.0 - 109.5 µs
time of flight resolution:
fixed at 000.01 µs
measurement update rate:
4, 8, 16, or max hz (16-20 hz depending on application and measurement mode)
transducerfrequency range:
2.25 - 30 mhz (35 & 35dl)
0.5 - 5.0 mhz (35hp & 35dl-hp)
min/max mode: displays current thickness, minimum or maximum thickness depending on setting.
display hold/blank: displays blanks after last reading or holds reading.
alarm mode: programmable hi-low alarm set points with audible and visual indicators
differential mode: displays thickness difference between actual measurement and reference value.
reduction rate mode: displays thickness and percent difference between actual measurement and reference value.
application auto-recall: automatically adjusts internal parameters for various default and custom transducer setups.
# of default
# of custom
35
21
10
35dl
21
20
35hp
17
10
35dl-hp
17
20
other standard features: calibration lock mode, internal diagnostic test mode, metric/english units, on-board statistics (35dl and 35dl-hp only)
power supply
battery: 3 aa alkaline or nimh batteries
operating time: 150 hours typical battery life; 30 hours continuous with backlight on
low battery indicator: continuously indicates battery status.
batterysaver: auto power off/continuous on
ac power supply: optional
general
environmental ip-65 compliant:
splash-proof, impact-resistant case. sealed, color-coded keypad with tactile and audible feedback.
operating temperature range:
-10°c to +50°c (+14°f to 122°f)
size: 3.31 w x 6.0 l x 1.50 h
(84 x 152 x 84 mm)
weight: 8.5 oz. (0.24 kg)
custom language utility: allows translation of display text in many languages.
35dl & 35dl-hp
internal data logger
data logger: the 35dl & 35dl-hp identify, store, recall, clear, and transmit thickness readings and transducer setup information via the usb port or optional rs-232.
max. # of stored values: over 8,000 or 350 waveforms with thickness readings (with waveform option)
stored data documentation: each saved thickness reading is fully documented with measurement status flags and a setup number that identifies parameters such as velocity, transducer, etc.
file name length: 8 alphanumeric characters
identification codes: 10 character alphanumeric identification code system identifies or locates stored data
4 file templates: incremental, sequential and 2d grid. manual files from pc.
standard inclusions
wrist strap, 3 aa batteries, test block, transducer cable, couplant, carrying case, instruction manual, two-year limited warranty
optional accessories
35/wf
live waveform
gageview
interface program
35dl/rs232
rs-232 output
35dlhp/rs232
rs-232 output
35pcscope
pcscope program
usb/adp-115
ac-115 power supply
usb/adp-230
ac-230 power supply
mg2/rpc
protective rubber boot
35/dlretro
upgrade 35 to 35dl
35hp/dlretro
upgrade 35hp to 35dl-hp
*all specifications are subject to change without notice.
some 35 series applications
wall thickness measurements for metal cans, containers and enclosures
thickness inspection of metal coils
measuring wall thickness of gun drilled metal
ultrasonic thickness measurements of hot metals
wall thickness measurements of metal pipes and tubes
on-line thickness gauging of extruded plastic
high temperature ultrasonic testing
ultrasonic couplants
measurements of silicone coatings on porcelain high voltage insulators
base curve and thickness measurement of soft contact lenses
ultrasonic measurements of liquids
thickness measurement of glass
thickness testing of reinforced rubber conveyor belts
measuring thickness of rubber tires
wall thickness measurements of rubber tires and bladders
thickness measurements on rubber sheets and coatings
thickness measurements on rubber hoses & tubing
measurement of fiberglass gelcoat
thickness gaging of fiberglass boat hulls
aerospace composites
thickness measurements of fiberglass plates, pipes and storage tanks
measuring nodularity in cast iron
measuring thickness of wax molds for precision castings
wall thickness measurement of cast engine blocks and cylinder bores
iron, steel, aluminum, and non-ferrous castings
ultrasonic testing in the foundry industry
wall thickness gaging in the blow molding industry
elastic modulus measurement